Choosing a PET Blower from Accepted Bottle Performance
Select a PET blower against the bottle drawing and preform, then define the required accepted output. Cavity count and theoretical cycle rate do not show whether the resulting bottle meets the packaging duty.

Use representative preforms
Keep the resin grade, weight and neck specification tied to the trial. Inspect wall distribution, dimensions and the agreed functional tests by cavity. Include startup samples and the normal production rate.
Compare the whole supply package
List moulds, air equipment, cooling, preform feeding and downstream transfer. Record utility conditions during testing. A blower-only price can omit equipment essential to reproduce the demonstration at the buyer’s plant.
Compare results by cavity
Label trial bottles by cavity and sampling time. If one cavity repeatedly produces a different base or wall distribution, compare its preform presentation, heating exposure, stretch alignment and cooling conditions. Averaging all bottles together can hide a local defect that remains after overall output reaches the target.
Need help planning your packaging line?